RADVision Scopia XT5000 Series Guía de instalación Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 113
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
Note
You can return to the Default Auto settings at any time by pressing and holding down the
Layout key and then pressing the 0 key.
You can configure your monitor so that the user sees two or three video streams on the
monitor(s): local video, remote video, and a data presentation.
PIP (Picture In Picture) displays two overlapped images on one monitor, where the remote
image is in full-screen format, and local image is in a smaller, overlapped window.
PaP (Picture and Picture) displays two images side-by-side on one monitor, where the
remote image and the local image have the same size, emulating a dual-monitor setup.
PoP (Picture out Picture) displays two images side-by-side on one monitor, where the
remote image is larger than the local image.
Procedure
Step 1
Access the general monitor settings as follows:
From the endpoint, select Configure > Advanced > I/O connections > Monitor >
General.
From the web interface, select Administrator settings > I/O connections > Monitor >
General.
Figure 5-26 Configuring the general monitor settings from the web interface
Step 2
Configure the settings as described in Table 5-10 on page 71.
RADVISION | Installation Guide for SCOPIA XT5000 Series Version 3.1 Initial Configuration | 70
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 112 113

Comentarios a estos manuales

Sin comentarios