Vista de pagina 153
Figure 99: GLAN1 port
Important:
If the GLAN2 port is enabled and in use, check that it is properly connected.
Solution
Assign a valid IP address to the system on GLAN1 or GLAN2, as described in
Configuring IP
Addresses on page 113.
Possible Causes
The system is capable of detecting IP/MAC addresses conflicts in a network. The conflict
occurs with static IP addresses if administrators have inadvertently attributed the same IP
addresses to devices or with dynamic IP addresses due to a DHCP server problem.
Solution
Verify that another the IP address defined for this endpoint is unique in the network. If there is
an address conflict, redefine the IP address.
If configuring from the endpoint, you must first enable advanced configuration, as described
in Maintaining the XT Endpoint Locally from the Endpoint on page 66.
1. From the endpoint's main menu, select Configure > Quick Setup.
2. Press Next several times until the Configure TCP/IP screen appears.
Figure 100: Configuring IP address
3. Enter the IP address.
Installation Guide for Scopia XT5000 Endpoint with Embedded